Liquid bitumen CUTBACK

https://gilsonite-bitumen.com/products/natural-asphalt/Liquid bitumen CUTBACK-1

Liquid bitumen CUTBACK

Cutback bitumen

Cutback bitumen means one section or cut return back. It is liquid and when you take the hydrocarbon from the bitumen it will get soft or hard so by adding solvent to the bitumen will convert to liquid form but under special specification of condition. Sometimes you need to quickly get cure and dry the solvent should be choose accordingly. There is different grade of cutback called Slow Curing, Medium Curing and Rapid Curing.

Cutback bitumen MC 30

In many places, cutback asphalt use is restricted to patching materials for use in cold weather cutback MC-30 is medium curing (MC) cut-back asphalt consisting of penetration grade asphalt cement and diluent or cutter of medium volatility. The diluent temporarily reduces the viscosity of the asphalt cement for ease of handling and application. After application the diluent evaporates, leaving asphalt cement to perform its function Petrochemical Trade Cutback MC-30 conforms to the specifications of ASTM D2127 (Medium-Curing Asphalt) or AASHTO M82The major use for Petrochemical Trade Cutback MC-30 is in the road maintenance industry where it is used as a prime coat of the base course prior to placing of the bituminous surface course. Its purpose is to bind the granular material of the base course to the asphalt layer. Usual application is by spray using a distributor.

PropertiesMinMaxTest Method
 Kinemalic 1 viscosity at 60°C, eSt3060ASTM D2170
 Flash Point (Tag Open-Cup),°C38ASTM D1310
 Distillate test 2 :   
 Distillate, percent by Volume of total 360°C 
 To 190°C15ASTM D402
 To 225°C2060ASTM D402
 To 260°C5090ASTM D402
 To 316°C8090ASTM D402
 Residue from distillation to 360°C: 
 Test on residue from distillation Penetration at
25°C,100g, 5 sec.
50 
 Ductility 3 at 25°C, cm120250ASTM D402 / ASTM D113
 Solubility in trichloroethylene, percent mass100ASTM D402 / ASTM D2024
 Water, percent volume0.2ASTM D95

Cutback bitumen MC 70

It is medium curing (MC) cut-back asphalt consisting of penetration grade asphalt cement and diluent or cutter of medium volatility. The diluent temporarily reduces the viscosity of the asphalt cement for ease of handling and application. After application the diluent evaporates, leaving asphalt cement to perform its function.Petrochemical Trade MC 70 conforms to the specifications of ASTM D2127 (Medium-Curing Asphalt) or AASHTO M82a) Roofing – As a waterproofing membrane and as an adhesive to stick chippings onto a flat, horizontal roof to minimize the effects of weathering from the sun.

PropertiesMinMaxTest Method
 Kinemalic 1 viscosity at 60°C, eSt70140ASTM D2170
 Flash Point (Tag Open-Cup),°C38ASTM D1310
 Distillate test 2 :   
 Distillate, percent by Volume of total 360°C 
 To 190°C15ASTM D402
 To 225°C2060ASTM D402
 To 260°C6590ASTM D402
 To 316°C55-sASTM D402
 Residue from distillation to 360°C: 
 Test on residue from distillation Penetration at
25°C,100g, 5 sec.
50 
 Ductility 3 at 25°C, cm120250ASTM D402 / ASTM D113
 Solubility in trichloroethylene, percent mass100ASTM D402 / ASTM D2024
 Water, percent volume0.2ASTM D95

Cutback bitumen MC 250

PropertiesMinMaxTest Method
 Kinemalic 1 viscosity at 60°C, eSt250500ASTM D2170
 Flash Point (Tag Open-Cup),°C66ASTM D1310
 Distillate test 2 :   
 Distillate, percent by Volume of total 360°C 
 To 190°C10ASTM D402
 To 225°C1555ASTM D402
 To 260°C6087ASTM D402
 To 316°C67ASTM D402
 Residue from distillation to 360°C: 
 Test on residue from distillation Penetration at
25°C,100g, 5 sec.
30120 
 Ductility 3 at 25°C, cm120250ASTM D402 / ASTM D113
 Solubility in trichloroethylene, percent mass100ASTM D402 / ASTM D2024
 Water, percent volume0.2ASTM D95

Cutback bitumen MC 800

Cutback MC-800 is a medium curing (MC) cut-back asphalt consisting of penetration grade asphalt cement and diluent or cutter of medium volatility.
The diluent temporarily reduces the viscosity of the asphalt cement for ease of handling and application. After application the diluent evaporates, leaving asphalt cement to perform its function.
Petrochemical Trade Cutback MC-800 conforms to the specifications of ASTM D2127 (Medium-Curing Asphalt) or AASHTO M82a) Roofing – As a waterproofing membrane and as an adhesive to stick chippings onto a flat, horizontal roof to minimize the effects of weathering from the sun.
b) Damp-Proof Courses – Used as damp-proof membranes in concrete floors particularly for small repairs or where extensions are keyed-in to existing structures.

PropertiesMinMaxTest Method
 Kinemalic 1 viscosity at 60°C, eSt8001600ASTM D2170
 Flash Point (Tag Open-Cup),°C60ASTM D1310
 Distillate test 2 :   
 Distillate, percent by Volume of total 360°C 
 To 190°C15ASTM D402
 To 225°C2060ASTM D402
 To 260°C5090ASTM D402
 To 316°C8090ASTM D402
 Residue from distillation to 360°C: 
 Test on residue from distillation Penetration at
25°C,100g, 5 sec.
50 
 Ductility 3 at 25°C, cm120250ASTM D402 / ASTM D113
 Solubility in trichloroethylene, percent mass100ASTM D402 / ASTM D2024
 Water, percent volume0.2ASTM D95

Cutback bitumen MC 3000

PropertiesMinMaxTest Method
 Kinemalic 1 viscosity at 60°C, eSt30006000ASTM D2170
 Flash Point (Tag Open-Cup),°C66ASTM D1310
 Distillate test 2 :   
 Distillate, percent by Volume of total 360°C 
 To 190°CASTM D402
 To 225°CASTM D402
 To 260°C15ASTM D402
 To 316°C80ASTM D402
 Residue from distillation to 360°C: 
 Test on residue from distillation Penetration at
25°C,100g, 5 sec.
80 
 Ductility 3 at 25°C, cm120250ASTM D402 / ASTM D113
 Solubility in trichloroethylene, percent mass100ASTM D402 / ASTM D2024
 Water, percent volume0.2ASTM D95

Cutback bitumen RC 30

Bitumen RC30 is dissolved of bitumen in solvents of kerosene. In many countries kerosene and other volatile petroleum derived products are added as a cutter or cutback agent to bitumen to reduce (or cutback) the viscosity of the bitumen. The mixture obtained may be called cutback bitumen.

The reduction in viscosity of the bitumen RC 30 aids the construction of seal coats in road pavements as the softened mixture wets the chips more easily. The cutback agent evaporates from the seal coat, the cutback agent becoming a negligible component of the seal coat a few months after application. If significant amounts of the cutback agent remain in the seal coat an unwanted long term softening effect may result.

PropertiesMinMaxTest Method
 Kinemalic 1 viscosity at 60°C, eSt3060ASTM D2170
 Flash Point (Tag Open-Cup),°CASTM D1310
 Distillate test 2 :   
 Distillate, percent by Volume of total 360°C 
 To 190°C15ASTM D402
 To 225°C55ASTM D402
 To 260°C75ASTM D402
 To 316°C90ASTM D402
 Residue from distillation to 360°C: 
 Test on residue from distillation Penetration at
25°C,100g, 5 sec.
80120 
 Ductility 3 at 25°C, cm100ASTM D402 / ASTM D113
 Solubility in trichloroethylene, percent mass100ASTM D402 / ASTM D2024
 Water, percent volume0.2ASTM D95

Cutback bitumen RC 70

 

PropertiesMinMaxTest Method
 Kinemalic 1 viscosity at 60°C, eSt70140ASTM D2170
 Flash Point (Tag Open-Cup),°CASTM D1310
 Distillate test 2 :   
 Distillate, percent by Volume of total 360°C 
 To 190°C10ASTM D402
 To 225°C50ASTM D402
 To 260°C70ASTM D402
 To 316°C85ASTM D402
 Residue from distillation to 360°C: 
Test on residue from distillation Penetration at 25°C,100g, 5 sec.55 
 Ductility 3 at 25°C, cm80120ASTM D402 / ASTM D113
 Solubility in trichloroethylene, percent mass100ASTM D402 / ASTM D2024
 Water, percent volume0.2ASTM D95

Cutback bitumen RC 250

Cutback bitumen RC250 is dissolved of bitumen in solvents of kerosene. In many countries kerosene and other volatile petroleum derived products are added as a cutter or cutback agent to bitumen to reduce (or cutback) the viscosity of the bitumen. The mixture obtained may be called cutback bitumen.

PropertiesMinMaxTest Method
 Kinemalic 1 viscosity at 60°C, eSt250500ASTM D2170
 Flash Point (Tag Open-Cup),°C27ASTM D1310
 Distillate test 2 :   
 Distillate, percent by Volume of total 360°C 
 To 190°CASTM D402
 To 225°C35ASTM D402
 To 260°C60ASTM D402
 To 316°C80ASTM D402
 Residue from distillation to 360°C: 
 Test on residue from distillation Penetration at
25°C,100g, 5 sec.
80120 
 Ductility 3 at 25°C, cm100ASTM D402 / ASTM D113
 Solubility in trichloroethylene, percent mass100ASTM D402 / ASTM D2024
 Water, percent volume0.2ASTM D95

Cutback bitumen RC 800

PropertiesMinMaxTest Method
 Kinemalic 1 viscosity at 60°C, eSt8001600ASTM D2170
 Flash Point (Tag Open-Cup),°C66ASTM D1310
 Distillate test 2 :   
 Distillate, percent by Volume of total 360°C 
 To 190°CASTM D402
 To 225°CASTM D402
 To 260°C35ASTM D402
 To 316°C4580ASTM D402
 Residue from distillation to 360°C: 
 Test on residue from distillation Penetration at
25°C,100g, 5 sec.
50 
 Ductility 3 at 25°C, cm120250ASTM D402 / ASTM D113
 Solubility in trichloroethylene, percent mass100ASTM D402 / ASTM D2024
 Water, percent volume0.2ASTM D95

Cutback bitumen SC 30

PROPERTIESMINMAXTEST METHOD
 KINEMALIC 1 VISCOSITY AT 60°C, EST3060ASTM D2170
 FLASH POINT (TAG OPEN-CUP),°C65ASTM D1310
 DISTILLATE TEST 2 :   
 DISTILLATE, PERCENT BY VOLUME OF TOTAL 360°C </ td>
 TO 190°CASTM D402
 TO 225°CASTM D402
 TO 260°CASTM D402
 TO 316°C1030ASTM D402
 RESIDUE FROM DISTILLATION TO 60°C:                      250        5000 
 TEST ON RESIDUE FROM DISTILLATION PENETRATION AT
25°C,100G, 5 SEC.
50 
 DUCTILITY 3 AT 25°C, CM100ASTM D402 / ASTM D113
 SOLUBILITY IN TRICHLOROETHYLENE, PERCENT MASS100ASTM D402 / ASTM D2024
 WATER, PERCENT VOLUME0.2ASTM D95

Cutback bitumen SC 70

PropertiesMinMaxTest Method
 Kinemalic 1 viscosity at 60°C, eSt70140ASTM D2170
 Flash Point (Tag Open-Cup),°C65ASTM D1310
 Distillate test 2 :   
 Distillate, percent by Volume of total 360°C 
 To 190°CASTM D402
 To 225°CASTM D402
 To 260°CASTM D402
 To 316°C1030ASTM D402
 Residue from distillation to 60°C:                      400        7000 
 Test on residue from distillation Penetration at
25°C,100g, 5 sec.
50 
 Ductility 3 at 25°C, cm100ASTM D402 / ASTM D113
 Solubility in trichloroethylene, percent mass100ASTM D402 / ASTM D2024
 Water, percent volume0.2ASTM D95

Cutback bitumen SC 250

PROPERTIESMINMAXTEST METHOD
 KINEMALIC 1 VISCOSITY AT 60°C, EST250500ASTM D2170
 FLASH POINT (TAG OPEN-CUP),°C80ASTM D1310
 DISTILLATE TEST 2 :   
 DISTILLATE, PERCENT BY VOLUME OF TOTAL 360°C 
 TO 190°CASTM D402
 TO 225°CASTM D402
 TO 260°CASTM D402
 TO 316°C420ASTM D402
 RESIDUE FROM DISTILLATION TO 60°C:                      800        10000 
 TEST ON RESIDUE FROM DISTILLATION PENETRATION AT
25°C,100G, 5 SEC.
60 
 DUCTILITY 3 AT 25°C, CM100ASTM D402 / ASTM D113
 SOLUBILITY IN TRICHLOROETHYLENE, PERCENT MASS100ASTM D402 / ASTM D2024
 WATER, PERCENT VOLUME0.2ASTM D95

Cutback bitumen SC 800

PROPERTIESMINMAXTEST METHOD
 KINEMALIC 1 VISCOSITY AT 60°C, EST250500ASTM D2170
 FLASH POINT (TAG OPEN-CUP),°C80ASTM D1310
 DISTILLATE TEST 2 :   
 DISTILLATE, PERCENT BY VOLUME OF TOTAL 360°C 
 TO 190°CASTM D402
 TO 225°CASTM D402
 TO 260°CASTM D402
 TO 316°C420ASTM D402
 RESIDUE FROM DISTILLATION TO 60°C:                      800        10000 
 TEST ON RESIDUE FROM DISTILLATION PENETRATION AT
25°C,100G, 5 SEC.
60 
 DUCTILITY 3 AT 25°C, CM100ASTM D402 / ASTM D113
 SOLUBILITY IN TRICHLOROETHYLENE, PERCENT MASS100ASTM D402 / ASTM D2024
 WATER, PERCENT VOLUME0.2ASTM D95
Article
TAGS